16.1. UPS activation

Use the following command to add the device.

[12:56:07] ABILIS_CPX:a dev:ups-1

COMMAND EXECUTED 

[12:56:22] ABILIS_CPX:d dev

- Not Saved (SAVE CONF) -------------------------------------------------------

------------------ Active PCI Devices and Physical Resources: -----------------
Device(s)   Run Physical Resource(s) or CTI Port(s)          SlotId  Addr  Irq
-------------------------------------------------------------------------------
ASY-1       Yes Async-1  . . . . . . . . . . . . . . . . . .      -   3F8    4
ETH-1       Yes Eth-1  . . . . . . . . . . . . . . . . . . .     18   PCI ( 15)
ETH-2       Yes Eth-2  . . . . . . . . . . . . . . . . . . .     72   PCI ( 15)
ETH-3       Yes Eth-3  . . . . . . . . . . . . . . . . . . .     73   PCI ( 11)
BSE-1       Yes 31..38, 101..140 . . . . . . . . . . . . . .     74   PCI ( 12)
UG-1        Yes 501..532 . . . . . . . . . . . . . . . . . .      -   PCI (  -)

------------------ Active USB Devices and Physical Resources: -----------------
Device(s)   Run Con Physical Resource(s) or CTI Port(s)    USBPORTID
-------------------------------------------------------------------------------
UPS-1       No  No  Ups  . . . . . . . . . . . . . . . . . NONE


----------------- Inactive PCI Devices and Physical Resources: ----------------
Device(s)   Run Physical Resource(s) or CTI Port(s)          SlotId  Addr  Irq
-------------------------------------------------------------------------------
                     *** NO INACTIVE PCI CARDs PRESENT ***                     

----------------- Inactive USB Devices and Physical Resources: ----------------
Device(s)   Run Con Physical Resource(s) or CTI Port(s)    USBPORTID
-------------------------------------------------------------------------------
                    *** NO INACTIVE USB DEVICEs PRESENT ***     
[Caution]Caution

After adding or setting the device active, you must restart the Abilis to make the device running (use the command warm start to reboot the Abilis).

The resource must be initialized using init res:ups-1.

[13:01:15] ABILIS_CPX:init res:ups-1

COMMAND EXECUTED

[13:01:26] ABILIS_CPX:d p ups-1

RES:Ups -----------------------------------------------------------------------
Run    DESCR:Uninterruptable_Power_Supply_device
       LOG:DS
       BATTERY-LOW-SHUTDOWN:YES        
       BATTERY-IN-USE-SOUND:DEFAULT
       - Sound pattern --------------------------------------------------------
       ON1:1000    OFF1:1000    ON2:1000    OFF2:57000   
       ON3:0       OFF3:0       ON4:0       OFF4:0       

The most important parameters are:

[13:01:37] ABILIS_CPX:d p ups-1 ?

Ups resource parameter(s):

DESCR:     Resource description. From 0 up to 79 Alphanumeric extended
           characters. Case is preserved. Spaces are allowed.
           Strings holding spaces must be written between quotation
           marks (E.g.: "str1 str2")
LOG:       State changes log and alarm generation [NO, D, S, A, L, T, ALL] [+E]
           (D: Debug Log; S: System Log; A: Alarm view; L: Local audible alarm;
            T: SNMP traps; +E: Extended Log of state changes, see ref. manual)
BATTERY-LOW-SHUTDOWN: Shutdown system if battery is the power source and 
                      battery level is low [NO, YES].
BATTERY-IN-USE-SOUND: Sound generated when system is powered by battery
                      [DEFAULT, DISABLED, CONTINUOUS, PATTERN].
---------- Sound pattern ------------------------------------------------------
ON1..ON4:  Duration of buzzer ON phase (sound is emitted) [0..300000 ms].
OFF1..OFF4: Duration of buffer OFF phase (silence) [0..300000 ms].

The most important parameters are:

DESCR

Resource description. From 0 up to 79 Alphanumeric extended characters. Case is preserved. Spaces are allowed. Strings holding spaces must be written between quotation marks (E.g.: "str1 str2")

LOG

State changes log and alarm generation [NO, D, S, A, L, T, ALL] [+E] (D: Debug Log; S: System Log; A: Alarm view; L: Local audible alarm; T: SNMP traps; +E: Extended Log of state changes, see ref. manual)

BATTERY-LOW-SHUTDOWN

Shutdown system if battery is the power source and battery level is low [NO, YES].

BATTERY-IN-USE-SOUND

Sound generated when system is powered by battery [DEFAULT - The buzzer is managed by UPS hardware autonomously, DISABLED - The buzzer is disabled, CONTINUOUS - The buzzer is continuous, PATTERN - A pattern is used to control the buzz].

ON1..ON4

Duration of buzzer ON phase (sound is emitted) [0..300000 ms].

OFF1..OFF4

Duration of buffer OFF phase (silence) [0..300000 ms].