To display the diagnostics of the UPS resource the following commands are used:
Shows diagnostic information, such as the state of the
resource (USB-STATE
), the uptime
(UPTIME
), the power source
(POWER-SOURCE
), the battery condition
(BATTERY
), the output regulated voltage value
(V-OUT
), the main power source voltage
(V-MAIN
), the charger state
(CHARGER
), the battery charging state
(CHARGING
) etc.
[13:42:55] ABILIS_CPX:d d ups
RES:Ups -----------------------------------------------------------------------
Uninterruptable_Power_Supply_device
USB-STATE:CONNECTED UPTIME:14 days 06:20:21 (22/07/2016 07:27:03)
POWER-SOURCE:MAIN BATTERY:NOT-PRESENT
V-OUT-ALARM:NO V-MAIN-ALARM:NO BATTERY-LOW:N/A
V-OUT:+12.1 V V-MAIN:+12.0 V V-BATT:+0.0 V
- Battery Charger ------------------------------------------------------
CHARGER:ENABLED CHARGING:NO
V-CHARGE:+13.9 V I-CHARGE:+0.0 A DUTY-CYCLE:50%
- Manual battery test result -------------------------------------------
TEST-ALLOWED:NO TEST-DELAY:N/A
LAST-RESULT:NOT-TESTED
LAST-EXECUTION:N/A
V-NO-LOAD:N/A V-START:N/A V-END:N/A
To display the statistics of the UPS resource the following commands are used:
Shows statistics information, such as the number sw/hw shutdown received from the UPS, the number of BATTERY LOW received from the UPS, the number of battery charger disconnection received from the UPS etc.
[13:48:36] ABILIS_CPX:d s ups
RES:Ups -----------------------------------------------------------------------
Uninterruptable_Power_Supply_device
--- Cleared 14 days 06:21:21 ago, on 22/07/2016 at 07:27:19 ------------
-----------|---INPUT---|--OUTPUT---|-----------|---INPUT---|--OUTPUT---|
SW-SHUTDOWN| | 0|V-MAIN-ALM | 0| |
HW-SHUTDOWN| 0| |V-OUT-ALM | 0| |
BATT-LOW | 0| | | | |
V-MAIN-FAIL| 0| |LIVE | | 1232374|
CHARGE-DIS | 0| |LIVE-EXP | 0| |
------------------------------------------------------------------------