The camera table holds the information about the RVS cameras.
[11:24:38] ABILIS_CPX:d p rvs
RES:Rvs-1 ---------------------------------------------------------------------
Run DESCR:Rvs Test
LOG:DS ACT:YES
- IpConf parameters (Read Only) ---------------------------------------
MAC:B8-27-EB-B3-A4-7A IPRES:Ip-1
IPADD:192.168.029.110 MASK:255.255.255.000 GW:192.168.029.254
-------+-------------------- Digital Input lines -----------------------
D-IN: | [DESCR:]
-------+----------------------------------------------------------------
-------+-------------------- Digital Output lines ----------------------
D-OUT: | [DESCR:]
| MODE: PULSE-T: PULSE-GAP: START: DFT:
-------+----------------------------------------------------------------
-------+-------------------------- Cameras -----------------------------
CAM: | [DESCR:]
| ACT: RESOLUTION: ROTATION: JPEG-QUALITY: EXPOSURE-TIME:
| HDR: FLASH: METERING:
| SHARPNESS: CONTRAST: BRIGHTNESS: SATURATION:
| STORAGE: REC-MAXAGE: IDLE-REC-INTERVAL:
| MIN-ALARM-DURATION: MAX-ALARM-DURATION:
| ALARM-HOLDOFF: LIVE-REC-DURATION:
-------+----------------------------------------------------------------
Cam-1 | Camera_1
| YES 5 270 LOW AUTO
| NO AUTO AVERAGE
| 0 0 0 0
| 5 (20 GiB) SYS SYS
| SYS SYS
| SYS SYS
------------------------------------------------------------------------
Meaning of the most important parameters:
DESCR
Resource description. From 0 up to 79 Alphanumeric extended characters. Case is preserved. Spaces are allowed. Strings holding spaces must be written between quotation marks (E.g.: "str1 str2")
LOG
State changes log and alarm generation [NO, D, S, A, L, T, ALL] [+E] (D: Debug Log; S: System Log; A: Alarm view; L: Local audible alarm; T: SNMP traps; +E: Extended Log of state changes, see ref. manual).
ACT
Operation activation [NO
,
YES
].
MAC
MAC address [00-00-00-00-00-00..FF-FF-FF-FF-FF-FF]. Read Only parameter.
IPRES
IP resource [NONE, Ip-1..Ip-250]. Read Only parameter.
IPADD
IP address in DDN [0.0.0.0, 0-126.x.x.x, 128-223.x.x.x]. Read Only parameter.
MASK
Mask in DDN [0.0.0.0, 240.0.0.0 - 255.255.255.255]. Read Only parameter.
GW
Gateway address in DDN [0.0.0.0, 0-126.x.x.x, 128-223.x.x.x]. Read Only parameter.
D-IN
Digital Input Line identifier [1..4].
D-OUT
Digital output Line identifier [1..4].
MODE
Operational mode [VALUE
,
PULSE
].
PULSE-T
Duration of ON pulse [1..4294967295 ms]. Only for MODE:PULSE.
PULSE-GAP
Minimum OFF time after ON pulse [1..65535 ms].
START
Initial value to be applied when Abilis connects to the
device [LAST
, DFT
]. If
"LAST
" and the last value is unknown or was
lost, the value specified in DFT
will be
used.
DFT
Default value to be used when there is not a known and valid value to set [OFF, ON].
CAM
Camera identifier [Cam-1..Cam-5 or 1..5]
ACT
Enable/disable this camera usage [NO
,
YES
].
RESOLUTION
Resolution [0.3, 1, 2, 5, 8 Mpx].
ROTATION
Image rotation in degrees relative to the camera [0, 90, 180, 270].
JPEG-QUALITY
Image compression ratio [LOW
,
MEDIUM
, HIGH
].
EXPOSURE-TIME
Exposure time, in fractions of a second [AUTO, 1/8, 1/15, 1/30, 1/60,1/125, 1/200, 1/250, 1/320, 1/400,1/500, 1/1000].
HDR
Enables/disables high dynamic range capture
[NO
, YES
].
FLASH
Flash mode [OFF
, AUTO
,
ON
].
METERING
Light metering mode [AVERAGE
,
CENTER
, MATRIX
,
BACKLIT
].
SHARPNESS
Sharpness [-10..+10].
CONTRAST
Contrast [-10..+10].
BRIGHTNESS
Brightness [-10..+10].
SATURATION
Saturation [-10..+10].
STORAGE
Number of 4 GiB files used for the storage [SYS, 2..1000].
When SYS
, the value is taken from
RES
:VS
configuration.
REC-MAXAGE
Images older than this value are deleted [SYS, NOMAX, 0,
1..365 day]. When 0, the recording is disabled. Use is restricted
to LIVE view. When NOMAX, the lifetime is unlimited. Images can be
deleted only manually or due to storage constrains. When
SYS
, the value is taken from
RES
:VS
configuration.
IDLE-REC-INTERVAL
Time interval between images capture during non-alarm
periods (idle) [SYS, 1..3600 s]. When SYS
, the
value is taken from RES
:VS
configuration.
MIN-ALARM-DURATION
Minimal duration of high frequency recording when the alarm
condition is detected [SYS, 10..3600 s] It will be extended up to
MAX-ALARM-DURATION if the alarm condition is detected again during
the ALARM-DURATION period. When SYS
, the value
is taken from RES
:VS
configuration.
MAX-ALARM-DURATION
Maximal duration of an alarm event [SYS, 10..3600 s]. When
SYS
, the value is taken from
RES
:VS
configuration.
ALARM-HOLDOFF
If an alarm is terminated by
MAX-ALARM-DURATION
an holdoff is introduced
before the next alarm is allowed [SYS, 0..3600 s]. When
SYS
, the value is taken from
RES
:VS
configuration.
LIVE-REC-DURATION
The maximum duration of LIVE mode recording [SYS, 10..3600
s]. When SYS
, the value is taken from
RES
:VS
configuration.
Caution | |
---|---|
To activate the changes, please execute the initialization command init res:rvs |
Tip | |
---|---|
Interesting chapter: Section 63.13.1.1, “Videorecorder cameras settings”. |
The camera table holds the information about the alarms related to an RVS cameras (up to 16 configurable alarms) .
[15:40:44] ABILIS_CPX:d vs alarm
-------------------------------------------------------------------------------
ID: |[DESCR:]
|ENABLED: |CAM-RES:|CAM: |TRIGGER:|RES: |IO:
|ACTION: |TURN-ON-RES: |TURN-ON-IO:
|TI1: |TI2:
|TI3: |TI4:
|TI5:
-------------------------------------------------------------------------------
0 [Test]
YES Rvs-1 Cam-1 OFF Rvs-1 D-IN-1
NONE #
ALL,00:00-23:59 #
# #
#
-------------------------------------------------------------------------------
Meaning of the most important parameters:
ENABLED
Enable/disable the alarm [NO
,
YES
].
CAM-RES
Resource that owns the activated camera [NONE, Rvs-1..Rvs-16].
CAM
Camera that will be activated [NONE, Cam-1..Cam-5 or 1..5].
TRIGGER
Alarm/event to be monitored [NONE, ON, OFF, *]
RES
Resource for which the alarm/event is monitored. "#" or "*" or "type-nnn" or "type-*" or the name of a CR (CPX resources) list between single quotes (e.g. * or Gpio-* or Mfio-1 or 'my_res_list').
IO
Input/output digital line for which the alarm/event is monitored.
#
: None;
D-IN-n
, where 'n' can be:
for GPIO Digital IN line, [1..16, *];
for MFIO Digital IN line, [1..7, *];
for RIO Digital IN line, [1..16, *];
for RVS Digital IN line, [1..4, *].
D-OUT-n, where 'n' can be:
for GPIO Digital OUT line, [1..16, *];
for MFIO Digital OUT line, [1..7, *].
for RIO Digital OUT line, [1..16, *];
for RVS Digital OUT line, [1..4, *].
Caution | |
---|---|
Only for Gpio/MfIo/Rio/Rvs resources. |
ACTION
Action to be executed when the monitored alarm/event occurs
[NONE
, MAIL
,
SMS
, DISA-CB
,
TURN-ON-D-OUT
]. Values can be joined using ","
operator.
MAIL
: Send a mail (SMTP driver must
be properly configured) and MAIL-FROM
and
MAIL-RCPT
parameters in VS port should
specify the sender and the recipient of the alarm mail.
SMS
: Send a SMS to SMS-CDO number
specified in the VS driver.
DISA-CB
: Perform a callback. Using
the DISA-* parameters in VS driver to match the related DISA
service.
TURN-ON-D-OUT
]: Turn on a digital
output (i.e. Turning on a light).
TURN-ON-RES
The resource whose output is set in case of alarm.. "#" or "type-nnn", where 'type' can be [Gpio, Mfio, Rio, Rvs].
TURN-ON-IO
The digital output that is set in case of alarm. "#" or "D-OUT-n", where 'n' can be:
for GPIO Digital OUT line, [1..16];
for MFIO Digital OUT line, [1..7].
for RIO Digital OUT line, [1..16, *];
for RVS Digital OUT line, [1..4, *].
Caution | |
---|---|
Only for |
TI1..TI5
Time interval within which the rule is active
[#
, ALL
,
*
, string in format day, hh:mm-hh:mm],
#
= disabled (i.e. 'no match'),
ALL
and *
= always. Value
'day' can be:
a single day of the week [MO, TU, WE, TH, FR, SA, SU];
a set of days of the week (E.g.: MO+TH or TU+TH+SU);
an interval of days of the week (E.g.: MO-WE or TH-SU);
ALL
.
Caution | |
---|---|
To activate the changes, please execute the initialization command init res:vs |
Tip | |
---|---|
Interesting chapter: Section 63.13.1.2, “Videorecorder alarms settings”. |