12.2. Simbox device activation

Use the following command to add the device.

[08:40:54] ABILIS_CPX:a dev:simbox-1

COMMAND EXECUTED

[08:40:58] ABILIS_CPX:d dev

- Not Saved (SAVE CONF) -------------------------------------------------------

------------------ Active PCI Cards and Physical Resources: -------------------
Card(s)     Run Physical Resource(s) or CTI Port(s)          SlotId  Addr  Irq
-------------------------------------------------------------------------------
ASY-1       Yes Async-1  . . . . . . . . . . . . . . . . . .      -   3F8    4
ETH-1       Yes Eth-1  . . . . . . . . . . . . . . . . . . .      9   PCI (  5)
ETH-2       Yes Eth-2  . . . . . . . . . . . . . . . . . . .      8   PCI ( 10)
ETH-3       Yes Eth-3  . . . . . . . . . . . . . . . . . . .     10   PCI ( 12)
BRI4-1      Yes 31..34 . . . . . . . . . . . . . . . . . . .     12   PCI ( 10)
POTS-1      Yes 101..116 . . . . . . . . . . . . . . . . . .     11   PCI (  9)
UG-1        Yes 201..232 . . . . . . . . . . . . . . . . . .      -   PCI (  -)
CB-1        Yes 241..248 . . . . . . . . . . . . . . . . . .      -   PCI (  -)

------------------ Active USB Devices and Physical Resources: -----------------
Device(s)   Run Con Physical Resource(s) or CTI Port(s)    USBPORTID
-------------------------------------------------------------------------------
ADSLUSB-1   Yes No  Adsl-1 . . . . . . . . . . . . . . . . NONE
CELLBOX-1           201..202 . . . . . . . . . . . . . . .
 CELL-1     Yes No  .  . . . . . . . . . . . . . . . . . . NONE
 CELL-2     Yes No  .  . . . . . . . . . . . . . . . . . . NONE
 CODEC-1    Yes No  .  . . . . . . . . . . . . . . . . . . NONE
 SIMEMU-1   Yes No  .  . . . . . . . . . . . . . . . . . . NONE
SIMBOX-1    No  No  SimBox-1 . . . . . . . . . . . . . . . NONE


----------------- Inactive PCI Cards and Physical Resources: ------------------
Card(s)     Run Physical Resource(s) or CTI Port(s)          SlotId  Addr  Irq
-------------------------------------------------------------------------------
                     *** NO INACTIVE PCI CARDs PRESENT ***

----------------- Inactive USB Devices and Physical Resources: ----------------
Device(s)   Run Con Physical Resource(s) or CTI Port(s)    USBPORTID
-------------------------------------------------------------------------------
                    *** NO INACTIVE USB DEVICEs PRESENT ***
[Caution]Caution

After adding or setting the device active, you must restart the Abilis to make the device running (use the command warm start to reboot the Abilis).

The following command is useful to enable the Simbox device.

[09:29:12] ABILIS_CPX:s p simbox-1 act:yes

COMMAND EXECUTED

[09:29:32] ABILIS_CPX:d p simbox-1

RES:SimBox-1 - Not Saved (SAVE CONF), Not Refreshed (INIT) --------------------
       ------------------------------------------------------------------------
       DESCR:
       LOG:NO        ACT:YES       mxps:512
       RSIM-RES:NONE
       RSIM-PWD:
[Caution]Caution

The resource must be initialized using init res:simbox-1.

The default parameters are sufficient to make the device working properly.At most a password may be configured to protect the access, but of course the same password must be used in all UMTS-BOX2 which need to connect to the SIMBOX.

[Tip]Tip

Interesting chapter:

Section 2.10.2, “UMTS-BOX2”;

Section 2.10.6, “Simbox”.

Use the classic Abilis CPX commands syntax to set the password (RSIM-PWD parameter):

[09:41:23] ABILIS_CPX:s p simbox-1 rsim-pwd:abilis

COMMAND EXECUTED

[09:41:32] ABILIS_CPX:d p simbox-1

RES:SimBox-1 - Not Saved (SAVE CONF), Not Refreshed (INIT) --------------------
       ------------------------------------------------------------------------
       DESCR:
       LOG:NO        ACT:YES        mxps:512
       RSIM-RES:NONE
       RSIM-PWD:********
[Caution]Caution

The resource must be initialized using init res:simbox-1.

The following are the simbox device parameters:

[09:39:44] ABILIS_CPX:d p simbox ?

SimBox resource parameter(s):

DESCR:     Resource description [Max. 80 aphanumeric extended characters]
LOG:       State changes log and alarm generation [NO, D, S, A, L, T, ALL] [+E]
           (D: Debug Log; S: System Log; A: Alarm view; L: Local audible alarm;
            T: SNMP traps; +E: Extended Log of state changes, see ref. manual)
ACT:       Operation activation [NO, YES]
mxps:      Maximal packet size in the packet exchange with RSIM [300..2048]
RSIM-RES:  RSim resource [NONE, RSim-XXX]
RSIM-PWD:  Password required to access this SIMBOX. From 0 up to 32 ASCII
           printable characters. Spaces are not allowed. Case is preserved.