The activation of SNMP resource allows to configure Abilis as a SNMP agent. The configuration is quite simple, because few parameters must be modified.
The MIB (Management Information Base) contains the description of the configuration/statistics “objects” available in the SNMP Agents and their availability to be controlled by SNMP Managers.The variables accessible via Abilis CPX SNMP resource are described in the Abilis proprietary MIB that can be downloaded from Abilis technical website - download section.
Note | |
---|---|
Access to download section is restricted, before proceeding you
need to obtain a valid username/password from Abilis technical support
( |
Refer to Section 42.5, “Appendix - SNMP Protocol” to have more information about SNMP protocol.
Add the resource to the Abilis system with the following command:
[15:50:39] ABILIS_CPX:a res:snmp
RES:SNMP ALREADY EXISTS
The SNMP resource may already exist in the system, but may not yet be active: set it active with the command:
[15:50:43] ABILIS_CPX:s act res:snmp
COMMAND EXECUTED
Caution | |
---|---|
After adding or setting the SNMP active, you must restart the Abilis to make the resource running (use the command warm start to reboot the Abilis). |
[17:14:59] ABILIS_CPX:s p snmp act:yes
COMMAND EXECUTED [17:15:17] ABILIS_CPX:d p snmp
RES:Snmp - Not Saved (SAVE CONF), Not Refreshed (INIT) ---------------------- ----------------------------------------------------------------------- Run DESCR:Simple_Network_Management_Protocol LOG:NO ACT:YES - Agent ---------------------------------------------------------------- locport:161 COMMUNITY:public IPSRC:* IPSRCLIST:# - Traps ---------------------------------------------------------------- TRAP:NO AUTHTRAP:NO TRAPREP:10 TRAPDEST:# TRAPSRC:R-ID (192.168.001.001)
Use the following command to display the parameters of the resource; the d p snmp ? command shows the meaning of parameters.
[09:58:41] ABILIS_CPX:
d p snmp
RES:Snmp ---------------------------------------------------------------------- Run DESCR:Simple_Network_Management_Protocol LOG:NO ACT:YES - Agent ---------------------------------------------------------------- locport:161 COMMUNITY:public IPSRC:* IPSRCLIST:# - Traps ---------------------------------------------------------------- TRAP:NO AUTHTRAP:NO TRAPREP:10 TRAPDEST:# TRAPSRC:R-ID (192.168.001.001)
Meaning of the most important parameters:
LOG
Logging functionalities activation/deactivation.
ACT
Runtime SNMP activation/deactivation.
COMMUNITY
Sets the keyword used by the authentication procedure of
those SNMP management systems able to query the SNMP Agent of the
Abilis CPX. Only those, which have the same value of the
“Community Name” as the local SNMP port, are allowed
to supervise. If it doesn't match, the query frames are rejected
and, if the parameter AUTHTRAP
is set to
YES
, a wrong authentication message is sent to
the SNMP Manager, whose IP is configured in the parameter
TRAPDEST
.
IPSRC
Sets the IP address of the SNMP source management from which the SNMP Agent of the Abilis can receive requests.
IPSRCLIST
Sets the list of the SNMP management systems able to query the SNMP Agent of the Abilis CPX.
TRAP
Enables/disables the generation of informative asynchronous
signalling (trap) to the SNMP Manager, which
IP address must be declared in the TRAPDEST
parameter.
AUTHTRAP
Enables/disables the generation of the wrong authentication signalling if SNMP resource receives requests from not authorized SNMP Manager processes.
TRAPREP
Sets the time interval (in minutes) which has to pass before resending the trap.
TRAPDEST
Sets the IP address (or a list of IP addresses) of the management system to which the TRAPS generated by the SNMP Agent of the Abilis must be sent.
TRAPSRC
Sets the source IP address to be used for outgoing traps.
The command that allows the configuration of the resource to be modified has the following syntax:
s p snmp
par:val
...
Caution | |
---|---|
To activate the changes made on the upper case parameters, execute the initialization command init res:snmp; while to set act the changes made on the lowercase parameters a save conf and an Abilis restart are required (i.e. with warm start command). |