Important | |
---|---|
This group is used for |
Enter into the Abilis control-program or open the configuration file with the Console configurator and type the following commands.
a ctig id:1 s:m | Add the multicast group. |
s ctig id:1 p1:sip cdo:200 | Add the SIP port with sip-number 200. |
s ctig id:1 p2:sip cdo:201 sp:8000 | Add the SIP port with sip-number 201 with SPOUT:8000. |
s ctig id:1 p3:sip cdo:202 coders:g.729a | Add the SIP port with sip-number 202 with CODERSOUT:G.729A. |
s ctig id:1 p4:sip cdo:203 t301:30 | Add the SIP port with sip-number 203 with alerting time-out 30 sec. |
save conf | Save the configuration. |
On a working Abilis, you must initialize the CTI Routings: init ctir.
Important | |
---|---|
The parameters (CDO, SP, CODERS, T301) of this example, replace
the corresponding parameters (CDO, SPOUT, CODERSOUT, T301) of the
routing when the group is configured in |
Tip | |
---|---|
Refer to chapter Section 47.5.1, “Display CTI Routing Table (D CTIR)” to know more about the CTI Routings parameters. Refer to chapter Section 47.3, “CTI Group” to know more about the CTI groups. |