If the POTSBOX is connected to the ELTI port to a non-expandable Abilis (MicroAbilis C3, PicoAbilis, etc.), then there isn't needed to activate it. The POTS ports will operate automatically after connecting the POTSBOX. Refer to the following chapter: Section 3.11, “POTSBOX connection”.
Important | |
---|---|
The numbering of POTS Ports for POTSBOX will be immediately following after on-board POTS ports of Abilis. |
Example: If you have BSE17 4-2-32 where the number of POTS on-board is 2 it result that the first port of POTSBOX is CTIP:103 for Abilis.
[15:30:26] ABILIS_CPX:d pcidev
PCI Server Overview:
ID Vendor Device CardName Slot/F Ver Irq
-------------------------------------------------------------------------------
0 1106 VIA 3123 BRIDGE HOST 0/0 0.00 -
1 1106 VIA B091 BRIDGE PCI NORMAL 1/0 0.00 -
2 3388 HINT CORP 0021 BRIDGE PCI NORMAL 8/0 1.05 -
3 104C TEXAS INST AC56 BRIDGE CARDBUS 9/0 0.00 15
4 1106 VIA 3038 USB HOST UHCI 16/0 8.00 15
5 1106 VIA 3038 USB HOST UHCI 16/1 8.00 11
6 1106 VIA 3038 USB HOST UHCI 16/2 8.00 12
7 1106 VIA 3104 USB HOST EHCI 16/3 8.02 10
8 1106 VIA 3177 BRIDGE ISA 17/0 0.00 -
9 1106 VIA 0571 STORAGE IDE 17/1 0.06 255
10 1106 VIA 3059 MULTIMEDIA AUDIO 17/5 5.00 12
11 1106 VIA 3065 NETWORK ETHERNET ETH-VT6102 18/0 7.04 15
12 1106 VIA 3122 DISPLAY VGA 32/0 0.03 15
13 10EC REALTEK 8139 NETWORK ETHERNET ETH-RTL8139 72/0 1.00 15
14 10EC REALTEK 8139 NETWORK ETHERNET ETH-RTL8139 73/0 1.00 11
15 10B5 PLX TECHNO 9030 NETWORK OTHER CTI-BSE17 4-2-32 74/0 2.00 12
16 1283 ITE 8872 NETWORK OTHER MFPCIGT 75/0 0.01 10
If the POTSBOX is connected to the ELTI port on the POTSHUB of expandable Abilis (Base-N, Base-P, etc.) then there is needed to activate the POTSHUB and the POTSBOX.
Use the command a dev:potshub-x to
add POTSHUB where
is the hardware
device identifier[1..3].x
[15:50:59] ABILIS_CPX:a dev:potshub-1
COMMAND EXECUTED [15:51:31] ABILIS_CPX:d dev
- Not Saved (SAVE CONF) ------------------------------------------------------- --------------- Active Watchdog and MFxx Resources (read only): --------------- Device(s) Run Physical Resource(s) SlotId Addr Irq ------------------------------------------------------------------------------- MF Yes Mf . . . . . . . . . . . . . . . . . . . . . - AC00 19 MFIO No MfIo . . . . . . . . . . . . . . . . . . . . - AC00 19 ------------------ Active PCI Devices and Physical Resources: ----------------- Device(s) Run Physical Resource(s) or CTI Port(s) SlotId Addr Irq -------------------------------------------------------------------------------- ASY-1 Yes Async-1 . . . . . . . . . . . . . . . . . . - 3F8 4 ETH-1 Yes Eth-1 . . . . . . . . . . . . . . . . . . . 18 PCI ( 5) ETH-2 Yes Eth-2 . . . . . . . . . . . . . . . . . . . 100 PCI ( 11) ETH-3 Yes Eth-3 . . . . . . . . . . . . . . . . . . . 101 PCI ( 5) POTSHUB-1 No . . . . . . . . . . . . . . . . . . . . . . NONE PCI ( -) POTSBOX-1 No 101..132 . . . . . . . . . . . . . . . . . . - PCI ( -) ------------------ Active USB Devices and Physical Resources: ----------------- Device(s) Run Con Physical Resource(s) or CTI Port(s) USBPORTID ------------------------------------------------------------------------------- DSLUSB-1 Yes Yes Dsl-1 . . . . . . . . . . . . . . . . 0.2 -------------- Inactive Watchdog and MFxx Resources (read only): -------------- Device(s) Run Physical Resource(s) SlotId Addr Irq ------------------------------------------------------------------------------- *** NO INACTIVE WATCHDOGs PRESENT *** ----------------- Inactive PCI Devices and Physical Resources: ---------------- Device(s) Run Physical Resource(s) or CTI Port(s) SlotId Addr Irq ------------------------------------------------------------------------------- *** NO INACTIVE PCI CARDs PRESENT *** ----------------- Inactive USB Devices and Physical Resources: ---------------- Device(s) Run Con Physical Resource(s) or CTI Port(s) USBPORTID ------------------------------------------------------------------------------- *** NO INACTIVE USB DEVICEs PRESENT ***
Important | |
---|---|
The max number of POTSHUB is 3. |
Use the command a
dev:potsbox-x to add POTSBOX where
x
is the hardware device identifier[1..12].
[15:59:26] ABILIS_CPX:a dev:potsbox-2
COMMAND EXECUTED [15:59:36] ABILIS_CPX:d dev
- Not Saved (SAVE CONF) ------------------------------------------------------- --------------- Active Watchdog and MFxx Resources (read only): --------------- Device(s) Run Physical Resource(s) SlotId Addr Irq ------------------------------------------------------------------------------- MF Yes Mf . . . . . . . . . . . . . . . . . . . . . - AC00 19 MFIO No MfIo . . . . . . . . . . . . . . . . . . . . - AC00 19 ------------------ Active PCI Devices and Physical Resources: ----------------- Device(s) Run Physical Resource(s) or CTI Port(s) SlotId Addr Irq ------------------------------------------------------------------------------- ASY-1 Yes Async-1 . . . . . . . . . . . . . . . . . . - 3F8 4 ETH-1 Yes Eth-1 . . . . . . . . . . . . . . . . . . . 18 PCI ( 5) ETH-2 Yes Eth-2 . . . . . . . . . . . . . . . . . . . 100 PCI ( 11) ETH-3 Yes Eth-3 . . . . . . . . . . . . . . . . . . . 101 PCI ( 5) POTSHUB-1 No . . . . . . . . . . . . . . . . . . . . . . NONE PCI ( -) POTSBOX-1 No 101..132 . . . . . . . . . . . . . . . . . . - PCI ( -) POTSBOX-2 No 133..164 . . . . . . . . . . . . . . . . . . - PCI ( -) ------------------ Active USB Devices and Physical Resources: ----------------- Device(s) Run Con Physical Resource(s) or CTI Port(s) USBPORTID ------------------------------------------------------------------------------- DSLUSB-1 Yes Yes Dsl-1 . . . . . . . . . . . . . . . . 0.2 -------------- Inactive Watchdog and MFxx Resources (read only): -------------- Device(s) Run Physical Resource(s) SlotId Addr Irq ------------------------------------------------------------------------------- *** NO INACTIVE WATCHDOGs PRESENT *** ----------------- Inactive PCI Devices and Physical Resources: ---------------- Device(s) Run Physical Resource(s) or CTI Port(s) SlotId Addr Irq ------------------------------------------------------------------------------- *** NO INACTIVE PCI CARDs PRESENT *** ----------------- Inactive USB Devices and Physical Resources: ---------------- Device(s) Run Con Physical Resource(s) or CTI Port(s) USBPORTID ------------------------------------------------------------------------------- *** NO INACTIVE USB DEVICEs PRESENT ***
Important | |
---|---|
The max number of POTSBOX is 12 (Up to 4 for each POTSHUB). The number of physical ports assigned for one POTSBOX is 32, even if we will use a POTSBOX with fewer ports 4,8.12 or 24. The not installed ports will appear as "Not running" and may be deactivated and hidden using the S INACT CTIP:xxx command. |